RADTRAD Software Error Notices
Expand the links below to see each respective error notification
-
QAP Error Notice 1 - Delay Time Implementation
-
When a user runs requests that a control room be added to the dose model the GUI
will generate a default breathing rate. If the user has previously specified a delay time, then
the default time versus breathing rate table has incorrect time values (they are not updated).
The end result is that RADTRAD will not execute (the code crashes).
-
Download PDF
-
QAP Error Notice 2 - Worst 2 Hour Incorrect
-
Calculation to determine the Worst 2 hour EAB dose can exceed array
length in at least one case. The resulting overwrite causes an incorrect value of the time
to be reported by the code. This does not result in erroneous dose values.
-
Download PDF
-
QAP Error Notice 3 - Consecutive Case Dose Changes
-
When a user runs the GUI version through the acceptance test case
sequence, some results are different from those calculated by the batch version. For
example test case 14 after test case 13 will have additional time periods edited, dose
results are not effected.
-
Download PDF
-
QAP Error Notice 4 - Consecutive Case Dose Changes
-
When a user runs the GUI version through the acceptance test case
sequence, some results are different from those calculated by the batch version. For
example test case 1a after test case 19 will have an incorrect value for the worst 2 hour
EAB dose. The edited value at 2 hours is correct.
-
Download PDF
-
QAP Error Notice 5 - Powers' Deposition Models
-
When a user chooses the Powers deposition models (either sprays or
natural decontamination) they go to the Aerosol Model Screen. The GUI indicates that the
percentile option has been initialized, but is not and results in a termination when the
calculate button is initiated.
-
Download PDF
-
QAP Error Notice 7 - Time Step Error (Control Room)(PWR reset)
-
The addition of offsite dose calculations to the control room dose
calculation reduced the control room dose by a factor of 2.
-
Download PDF
-
QAP Error Notice 8 - Powers' Natural Deposition
-
Unknown to the user, the RADTRAD 3.03 GUI automatically modifies any
compartment, using Powers' Natural Deposition, to the "PWR Design Basis"
containment model, whenever the panel for that given compartment is opened. Therefore, the
compartment panel cannot be viewed without one having to return the selection to whatever
containment model that the user desired. (Mscisz) The program has a case set-up screen for options where the user selects the reactor type
to determine fission product species for the event and a separate selection of the Powers
aerosol decontamination factor. Normally if a case is created, saved, and then executed
the selected options are used. If a case is re-opened, to check or correct the data inputs
for example, the program automatically resets the options to PWR - DBA and 10th percentile
Powers aerosol decontamination factor. If the case is then run without checking these
options then the case is executed with the defaults.(Re)
-
Download PDF
-
QAP Error Notice 9 - More Than 9 Compartments
-
Do you know of any previously reported error in RADTRAD associated with
the use of all 10 Volumes? Two of us have separately run into problems when specifying a
10th volume in two separate models. It seems that when the 10th volume is specified, it
somehow alters the source term associated with Volume #1.
-
Download PDF
-
QAP Error Notice 10 - Time Step Error (Daughtering)
-
When running RADTRAD with reduced time steps the code generates different inventories for some nuclides.
-
Download PDF
-
QAP Error Notice 11 - Time Step Error (Daughtering)
-
When running RADTRAD with only Tellurium nuclides why is the concentration of iodine daughters so low?
-
Download PDF
-
QAP Error Notice 12 - Powers' Natural Deposition (time steps not included)
-
When running RADTRAD with Powers' Natural Deposition model, the code
generates inventories at 24 hours that may vary by as much as 2% when I add time
intervals.
-
Download PDF
-
QAP Error Notice 13 - Time Step Error (Abrupt Flow Changes)
-
User defined time steps can give different results when the flow changes
abruptly.
-
Download PDF
-
QAP Error Notice 14 - Powers' Spray Model
-
The RADTRAD V303 FORTRAN logic does not define the spray alpha as the
Powers model does, they should be consistent. This error also generates conservative
(higher dose) results.
-
Download PDF
-
QAP Error Notice 15 - User Defined Natural Deposition
-
When using the natural deposition User input option, if the User does not
specify a set of aerosol deposition values the code fails.
-
Download PDF
-
QAP Error Notice 16 - Split Source Term
-
If a user models a timed release with the source term split from two
separate compartments, the radionuclides available for release are incorrectly reduced.
-
Download PDF
-
QAP Error Notice 17 - Powers' Natural Deposition (deposition after 24 hours)
-
The Powers simplified model for natural deposition of radionuclides included
a feature to stop all deposition at around 24hours due to limitations in the underlying physics.
This feature was not included in all versions of the RADTRAD code, instead a nominal removal
coefficient was used. Thus additional deposition occurred over the ensuing 29 days leading to
a potential for less release from the containment and therefore less personnel dose.
-
Download PDF
-
QAP Error Notice 18 - Deposition Model Output Errors
-
The RADTRAD software allows the user to model certain compartment features, including
radionucleid removal via Sprays and Natural Deposition. The runtime model information
(if selected) displayed in the output file is mislabeled for certain situations. This
error has two effects, which apply to both RADTRAD 3.03 and Serco-RADTRAD v3.10 unless
otherwise stated in the description.
-
Download PDF
|